I have run into a problem with production line tool, during final production of our circuit, a battery will already be attached and there will be no way to power cycle the DA14580 to load the programming firmware. Is it possible to have the PLT assert resets instead of relying on power on resets for the programming process?

Device:
Gongyu_Dialog
Offline
Last seen:5 days 2 hours ago
加入:2016-04-27 07:07
I am afraid that the current

I am afraid that the current PLT firmware doesn't support the reset function.
We will plan to add it in the next released PLT software version.

But for test, may recommend to add an RC circuit to simulate the reset signal as the attachment file.

Attachment:
Dave.Renzo
Offline
Last seen:2 years 7 months ago
加入:2015-10-08 13:21
I kind of had a bit tunnel

我有一点视野狭窄,没完没了g I had to change the firmware to get the functionality I wanted. Your suggestion is a great idea, though I think it would work better if there was an inverter in place of the RC circuit. I'm going to experiment with this and will let you know how it turns out. Thanks again.