I was prepare the mass production by Production Line Tool(ver. 3.170.2.36). 但在执行屏幕,我不能检查DUT16年代tatus becasue of the screen is cut off. Please check my attached file.
Just had a mail from the PLT specialist, there must be something wrong with your screen setup (windows), you are missing parts of the screen. What is your screen resolution, can you please try another one ?
Hi build77,
Can you please upload the params.ini file or some more screen shots of all the screens. Also can you please try to reinstall the software ?
Thanks MT_dialog
Thanks dialog
I just updated all screen.
I also re-install several times, and problem is same.
My params.ini is bellow.
Very Thanks.
-----------------------------------------------
------------- PLT Configuration ---------------
-----------------------------------------------
-----------------------------------------------
------------- Execution -----------------------
-----------------------------------------------
tests_enable = true
programming_enable = true
-----------------------------------------------
------------- GPIOs ---------------------------
-----------------------------------------------
uart_boot_pins = 0
uart_programming_enable = false
uart_port_tx = 0
uart_pin_tx = 0
uart_port_rx = 0
uart_pin_rx = 1
baud_rate = 115200
vpp_control_port = 1
vpp_control_pin = 2
vpp_control_enable = false
spi_pins_enable = false
spi_clk_port = 0
spi_clk_pin = 0
spi_di_port = 0
spi_di_pin = 5
spi_do_port = 0
spi_do_pin = 6
spi_cs_port = 0
spi_cs_pin = 3
i2c_pins_enable = false
i2c_scl_port = 0
i2c_scl_pin = 2
i2c_sda_port = 0
i2c_sda_pin = 3
xtal_trim_gpio_port = 0
xtal_trim_gpio_pin = 1
-----------------------------------------------
------------- Test Settings -------------------
-----------------------------------------------
rf_test_enable_1 = true
rssi_limit_1 = -70.000000
frequency_1 = 2450
rf_test_enable_2 = false
rssi_limit_2 = -70.000000
frequency_2 = 2402
rf_test_enable_3 = false
rssi_limit_3 = -70.000000
frequency_3 = 2402
audio_test_enable = false
audio_pwr_lvl = 0000
xtal_trim_enable = false
xtal_trim_burn_otp = false
custom_data_enable = false
custom_data_value = 00
scan_enable = false
-----------------------------------------------
------------- Memory Functions ----------------
-----------------------------------------------
otp_write_enable = true
otp_readback = true
otp_image_path = D:\DA14580\DA14580_Production_Line_Tool_v_3.170.2.36\executables\binaries\prox_reporter_16B2.bin
spi_write_enable = false
spi_readback = false
spi_bootable = false
spi_start_addr = 0000
spi_image_path =
eeprom_write_enable = false
eeprom_readback = false
eeprom_bootable = false
eeprom_start_addr = 0000
eeprom_image_path =
-----------------------------------------------
------------- OTP Header -----------------------
-----------------------------------------------
otp_write_header = true
otp_header_readback = true
bd_addr_load_from_file = true
bd_address_file_path = D:\DA14580\DA14580_Production_Line_Tool_v_3.170.2.36\executables\params\bd_address.ini
start_bd_addr = CC:1B:E0:00:04:22
otp_xtal16_trim_val = 00:00:04:4C
otp_xtal16_trim_flag = true
otp_jtag_enable = true
otp_32khz_source = 1
otp_dma_len = 00:00:16:B2
sw_customer_field = false
otp_customer_field_1 = 00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:00
otp_customer_field_2 = 00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:00
otp_customer_field_3 = 00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:00
otp_customer_field_4 = 00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:00
otp_customer_field_5 = 00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:00
otp_customer_field_6 = 00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:00
otp_customer_field_7 = 00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:00
otp_customer_field_8 = 00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:00
otp_customer_field_9 = 00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:00
otp_customer_field_10 = 00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:00
otp_customer_field_11 = 00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:00
otp_customer_field_12 = 00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:00
otp_customer_field_13 = 00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:00
otp_customer_field_14 = 00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:00
otp_customer_field_15 = 00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:00
otp_customer_field_16 = 00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:00
otp_appl_flags_1_2 = true
-----------------------------------------------
------------- HW Setup ------------------------
-----------------------------------------------
station_id = Test_05
dut_ic = 0
dut_num_1 = false
dut_num_2 = false
dut_num_3 = false
dut_num_4 = true
dut_num_5 = false
dut_num_6 = false
dut_num_7 = false
dut_num_8 = false
dut_num_9 = false
dut_num_10 = false
dut_num_11 = false
dut_num_12 = false
dut_num_13 = false
dut_num_14 = false
dut_num_15 = false
dut_num_16 = false
gu_com_port = 29
-----------------------------------------------
------------- Debug Settings ------------------
-----------------------------------------------
ui_debug_enable = false
ui_debug_output_stdio = false
ui_debug_output_file = false
ui_debug_output_clbk = false
ui_debug_level_error = false
ui_debug_level_info = false
ui_debug_level_debug = false
ui_debug_file_path = X:\2014\Smart 보청기\SW\Dailog\src\SDK_3.0.10.1\DA14580_Production_Line_Tool_v_3.170.2.36\DA14580_Production_Line_Tool_v_3.170.2.36\executables\UI_debug.txt
pltd_debug_enable = false
pltd_debug_output_stdio = false
pltd_debug_output_file = false
pltd_debug_output_clbk = false
pltd_debug_level_error = false
pltd_debug_level_info = false
pltd_debug_level_debug = false
pltd_debug_file_path = X:\2014\Smart 보청기\SW\Dailog\src\SDK_3.0.10.1\DA14580_Production_Line_Tool_v_3.170.2.36\DA14580_Production_Line_Tool_v_3.170.2.36\executables\PLTD_debug.txt
pdll_debug_enable = false
pdll_debug_output_stdio = false
pdll_debug_output_file = false
pdll_debug_output_clbk = false
pdll_debug_level_error = false
pdll_debug_level_info = false
pdll_debug_level_debug = false
pdll_debug_file_path = X:\2014\Smart 보청기\SW\Dailog\src\SDK_3.0.10.1\DA14580_Production_Line_Tool_v_3.170.2.36\DA14580_Production_Line_Tool_v_3.170.2.36\executables\PDLL_debug.txt
udll_debug_enable = false
udll_debug_output_stdio = false
udll_debug_output_file = false
udll_debug_output_clbk = false
udll_debug_level_error = false
udll_debug_level_info = false
udll_debug_level_debug = false
udll_debug_file_path = X:\2014\Smart 보청기\SW\Dailog\src\SDK_3.0.10.1\DA14580_Production_Line_Tool_v_3.170.2.36\DA14580_Production_Line_Tool_v_3.170.2.36\executables\UDLL_debug.txt
Hi build77,
Just had a mail from the PLT specialist, there must be something wrong with your screen setup (windows), you are missing parts of the screen. What is your screen resolution, can you please try another one ?
Thanks MT_dialog