2 posts / 0 new
Last post
Björn Haase
Offline
Last seen:7 years 2 months ago
加入:2014-01-09 14:24
M0 Core variant used in DA14580

Which variant of the M0 Core family has been used within the DA14580 family.

Specifically, which type of multiplier option has been designed-in? The 32 cycle multiplier or the single-cycle multiplier?

FvD_Dialog
Offline
Last seen:1 month 1 week ago
Staff
加入:2013-12-05 14:41
Dear Björn,

Dear Björn,
We are using the single cycle multiplier option.