Hi All,
I am currently evaluating the DA14580 and would like to find out the requirements for the external 32kHz.
数据表州32 khz外部osc is used as the clock of the extended/deep sleep modes. If I plan on using this in beacon only mode (sleep power is critical), would I be able to achieve this using the internal 32kHz osc only?
Thanks,
Louis
Keywords:
Device:
generally, we prefer to use external 32K osc.
32KHz Oscillator:
No limits on connection interval time.
No limits on temperature change slope
Internal RCX20:
Temperature change limited to max. 5°C/min
Connection interval time limited to max. 2 sec
need to calibrate each time of connection interval