生产线工具执行屏幕

4个职位/ 0个新职位
最后发表
build77
离线
最后看到:1个月1个星期前
加入:2015-02-17 02:32
生产线工具执行屏幕

嗨,对话

我正在准备大量生产的生产线工具(ver。3.170.2.36)。
但在Execute屏幕中,我无法检查DUT16状态,屏幕的屏幕被切断。
请查收我的附件。

非常谢谢。

问候,

设备:
MT_dialog
离线
最后看到:6个月2个星期前
工作人员
加入:2015-06-08 11:34
嗨build77,

嗨build77,

你能上传params.ini文件或更多的屏幕截图吗?你能试着重新安装这个软件吗?

由于MT_dialog

build77
离线
最后看到:1个月1个星期前
加入:2015-02-17 02:32
谢谢对话框

谢谢对话框

我刚刚更新了所有屏幕。
我也重新安装了几次,问题是一样的。

我的params.ini是吼声的。
非常谢谢。

-----------------------------------------------
------------- PLT配置--------------
-----------------------------------------------

-----------------------------------------------
------------- 执行 -----------------------
-----------------------------------------------
tests_enable = true
编程_enable = true
-----------------------------------------------
------------- GPIOs ---------------------------
-----------------------------------------------
uart_boot_pins = 0
uart_programming_enable = false
uart_port_tx = 0
UART_PIN_TX = 0.
uart_port_rx = 0
uart_pin_rx = 1
baud_rate = 115200
vpp_control_port = 1
vpp_control_pin = 2
vpp_control_enable = false.
spi_pins_enable = false
spi_clk_port = 0.
spi_clk_pin = 0
spi_di_port = 0
spi_di_pin = 5
spi_do_port = 0
spi_do_pin = 6
spi_cs_port = 0
spi_cs_pin = 3.
i2c_pins_enable = false
i2c_scl_port = 0
i2c_scl_pin = 2
i2c_sda_port = 0
i2c_sda_pin = 3
xtal_trim_gpio_port = 0
xtal_trim_gpio_pin = 1
-----------------------------------------------
-------------测试设置-----------------
-----------------------------------------------
rf_test_enable_1 = true
rssi_limit_1 = -70.000000
frequency_1 = 2450
rf_test_enable_2 = false
rssi_limit_2 = -70.000000
frequency_2 = 2402
rf_test_enable_3 = false.
rssi_limit_3 = -70.000000
frequency_3 = 2402
audio_test_enable = false
audio_pwr_lvl = 0000
xtal_trim_enable = false.
xtal_trim_burn_otp = false
custom_data_enable = false
custom_data_value = 00
scan_enable = false
-----------------------------------------------
-------------内存功能----------------
-----------------------------------------------
otp_write_enable = true
otp_readback = true
otp_image_path = D: \ DA14580 \ \ prox_reporter_16B2.bin DA14580_Production_Line_Tool_v_3.170.2.36 \可执行文件\二进制文件
spi_write_enable = false
spi_readback = false
spi_bootable = false
spi_start_addr = 0000.
spi_image_path =.
EEPROM_WRITE_ENABLE = FALSE.
eeprom_readback = false
eeprom_bootable = false
eeprom_start_addr = 0000
EEPROM_IMAGE_PATH =.
-----------------------------------------------
------------- OTP报头-----------------------
-----------------------------------------------
otp_write_header = true
otp_header_readback = true
bd_addr_load_from_file = true
bd_address_file_path = D: \ \ params \ bd_address.ini DA14580 \ DA14580_Production_Line_Tool_v_3.170.2.36 \可执行文件
start_bd_addr = CC: 1 b: E0:00:04:22
otp_xtal16_trim_val = 00:00:04:4C
otp_xtal16_trim_flag = true
otp_jtag_enable = true
otp_32khz_source = 1
otp_dma_len = 00:00:16: B2
sw_customer_field = false
otp_customer_field_1 = 00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:00
otp_customer_field_2 = 00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:00
OTP_CUSTOMER_FIELD_3 = 00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:00
otp_customer_field_4 = 00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:00
otp_customer_field_5 = 00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:00
otp_customer_field_6 = 00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:00
otp_customer_field_7 = 00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:00
OTP_CUSTOMER_FIELD_8 = 00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:00
otp_customer_field_9 = 00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:00
otp_customer_field_10 = 00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:00
otp_customer_field_11 = 00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:00
otp_customer_field_12 = 00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:00
otp_customer_field_13 = 00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:00
otp_customer_field_14 = 00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:00
otp_customer_field_15 = 00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:00
otp_customer_field_16 = 00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:00
otp_appl_flags_1_2 = true
-----------------------------------------------
------------- HW Setup ------------------------
-----------------------------------------------
station_id = test_05.
dut_ic = 0
dut_num_1 = false.
dut_num_2 = false
dut_num_3 = false
dut_num_4 = true
dut_num_5 = false
dut_num_6 = false
dut_num_7 = false
dut_num_8 = false
dut_num_9 = false.
dut_num_10 = false
dut_num_11 = false.
dut_num_12 = false
dut_num_13 = false.
dut_num_14 = false.
dut_num_15 = false
dut_num_16 = false
gu_com_port = 29
-----------------------------------------------
-------------调试设置------------------
-----------------------------------------------
ui_debug_enable = false
Ui_debug_output_stdio = false.
Ui_debug_output_file = false.
ui_debug_output_clbk = false
ui_debug_level_error = false
ui_debug_level_info = false
ui_debug_level_debug = false.
ui_debug_file_path = X: \ 2014 \智能보청기\ \ Dailog \ src \西南SDK_3.0.10.1 \ \ UI_debug.txt DA14580_Production_Line_Tool_v_3.170.2.36 \ DA14580_Production_Line_Tool_v_3.170.2.36 \可执行文件
pltd_debug_enable = false
pltd_debug_output_stdio = false.
pltd_debug_output_file = false
pltd_debug_output_clbk = false.
pltd_debug_level_error = false
pltd_debug_level_info = false.
pltd_debug_level_debug = false.
pltd_debug_file_path = X: \ 2014 \智能보청기\ \ Dailog \ src \西南SDK_3.0.10.1 \ \ PLTD_debug.txt DA14580_Production_Line_Tool_v_3.170.2.36 \ DA14580_Production_Line_Tool_v_3.170.2.36 \可执行文件
pdll_debug_enable = false
pdll_debug_output_stdio = false.
pdll_debug_output_file = false
pdll_debug_output_clbk = false
pdll_debug_level_error = false
pdll_debug_level_info = false.
pdll_debug_level_debug = false
pdll_debug_file_path = x:\ 2014 \ smart보청기\ sw \ dailog \ src \ sdk_3.0.10.1 \ da14580_production_line_tool_v_3.170.36 \ da14580_production_line_tool_v_3.170.2.36 \可执行文件\ pdll_debug.txt
udll_debug_enable = false
udll_debug_output_stdio = false.
udll_debug_output_file = false
udll_debug_output_clbk = false
udll_debug_level_error = false
udll_debug_level_info = false
udll_debug_level_debug = false.
udll_debug_file_path = X: \ 2014 \智能보청기\ \ Dailog \ src \西南SDK_3.0.10.1 \ \ UDLL_debug.txt DA14580_Production_Line_Tool_v_3.170.2.36 \ DA14580_Production_Line_Tool_v_3.170.2.36 \可执行文件

附件:
MT_dialog
离线
最后看到:6个月2个星期前
工作人员
加入:2015-06-08 11:34
嗨build77,

嗨build77,

刚从PLT专家寄到邮件,您的屏幕设置(Windows)必须出现问题,您缺少屏幕的部分。你的屏幕解决是什么,你能试试另一个吗?

由于MT_dialog