Hi there.. thanks for coming to the forums. Exciting news! we’re now in the process of moving to our new forum platform that will offer better functionality and is contained within the main Dialog website. All posts and accounts have been migrated. We’re now accepting traffic on the new forum only - please POST any new threads at//www.wsdof.com/support. We’ll be fixing bugs / optimising the searching and tagging over the coming days.
9 posts / 0 new
Last post
kerrda
Offline
Last seen:1 year 9 months ago
Joined:2019-07-05 18:06
功能插座测试失败了。套接字问题发现ted.

Hello

Im using SLG46826V on the dev board. I get this error whenever I connect an input from an ardiuno onto one of the test points. What is causing this issue? I have included a picture of the error and my two inputs are on TP2 and TP4

Attachment:
Device:
Device Number:
SLG46826V
ivnn
Offline
Last seen:1 year 4 months ago
Joined:2019-07-03 10:42
Hi, pls post complete

Hi, pls post complete schematic for analysis

kerrda
Offline
Last seen:1 year 9 months ago
Joined:2019-07-05 18:06
Didnt think to ask this in

Didnt think to ask this in the original post, will using a 3.3V input be casuing this error, while the greenPAK design is using a 5V rail?

ivnn
Offline
Last seen:1 year 4 months ago
Joined:2019-07-03 10:42
You can build voltage

You can build voltage translator inside greenpack for each Arduino input

kerrda
Offline
Last seen:1 year 9 months ago
Joined:2019-07-05 18:06
Im still receiving the issue

Im still receiving the issue with 5V input, heres my schematic

Attachment:
pavloZ
Offline
Last seen:1 year 1 month ago
Staff
Joined:2018-01-31 12:50
Hi Sean,

Hi Sean,

this error caused board's external connections during socket test. You can turn-off (disconnect) buffered expander connector in debug tool before starting emulation and then turn them on. Do not use test points on the devboard for any external connections except measurment tools. It doesn't depend on VDD rail or design configuration. Please let me know if you have any questions.

kerrda
Offline
Last seen:1 year 9 months ago
Joined:2019-07-05 18:06
Thanks for the reply PavloZ,

Thanks for the reply PavloZ,

So i cannot connect inputs into any test points? How am I supposed to do testing on my chip then?

pavloZ
Offline
Last seen:1 year 1 month ago
Staff
Joined:2018-01-31 12:50
Hi Sean,

Hi Sean,

yes, test points are dedicated only for test equipment (scope, volmeter). Supplying voltage, shorting or connectin load can cause devboard damadge. There are expansion connector on the devboard. It has buffered IOs whith protection and on/off function. Please use that connector to test any of your circuit.

Thanks.

pavloZ
Offline
Last seen:1 year 1 month ago
Staff
Joined:2018-01-31 12:50
Please use expansion

Please use expansion connector

//www.wsdof.com/sites/default/files/greenpak_advanc...

page 5, figure 1.