Hi there.. thanks for coming to the forums. Exciting news! we’re now in the process of moving to our new forum platform that will offer better functionality and is contained within the main Dialog website. All posts and accounts have been migrated. We’re now accepting traffic on the new forum only - please POST any new threads at//www.wsdof.com/support. We’ll be fixing bugs / optimising the searching and tagging over the coming days.
2 posts / 0 new
Last post
MSchell007
Offline
Last seen:3 months 1 week ago
加入:2019-04-23 20:09
DA9070巴克调节器上启用升高?

Just want to verify that the buck converter is enabled by default on power-up. On page 106 of the datasheet, Buck Enable is shown to be a zero on power-up. Should this be described as a "Buck Enable Not" function? A zero in bit 7 of register 0x0030 enables the buck output? I assume the default output is 2.0V. Thanks.

Device:
ED_Dialog
Offline
Last seen:3 weeks 3 days ago
Staff
加入:2017-09-18 11:54
Hello,

Hello,

The DA9070/73 are OTP programmed devices, so the set-up of the device is dependent on the OTP configuration. whether the buck is enabled and what output voltage it is set to is dependent on the OTP settings. Our demo boards have the Buck enabled by default, however it is possible and to have the Buck disabled by default and set to different voltages.