Hello.
I've recently received the DA14585 Pro Kit.
I have configured my DA14585 as a central and have had it successfully scanning for, connected to and read writing a peripheral.
When I returned this morning I no longer see my peripheral in the scan results ( via callback .app_on_adv_report_ind ) thought I did see it before.
I do get scan responses from other peripherals, however.
I can confirm my peripheral is running because I can see and connect to my peripheral using my Smartphone Apps (e.g. nRF Connect).
There are no other central's connected to my peripheral when I am scanning for it.
Is there some configuration flag or setting that filter's the scan results and only show's me devices I have not connected to?
If so how/where do i clear that flag? Do I need to erase the flash?
My user_config.h is attached as pdf
谢谢你your time
Hi There, i'll contact you directly via emial. BR JE_Dialog
Hi ojazdowski,
谢谢你your question. I will reach out you directly.
Regards, PM_Dialog
你好。谢谢你getting back in touch.
As it stands my peripharal configuration had been changed to "non-pairable."
My Central was configured as "GAP_GEN_DISCOVERY."
This combination stopped be from seeing the peripheral in the scan response.
Changing by CENTRAL configuration to "GAP_OBSERVER_MODE" fixed the issue.
I can now see the peripheral and connect.
Why would this be?
Thanks
Hi ojazdowski,
I will contact you directly.
Thanks, PM_Dialog