SLG46826 factory setting for IO6?

⚠️
Hi there.. thanks for coming to the forums. Exciting news! we’re now in the process of moving to our new forum platform that will offer better functionality and is contained within the main Dialog website. All posts and accounts have been migrated. We’re now accepting traffic on the new forum only - please POST any new threads at//www.wsdof.com/support. We’ll be fixing bugs / optimising the searching and tagging over the coming days.
7 posts / 0 new
Last post
lottabull
Offline
Last seen:6 months 2 weeks ago
加入:2018-03-02 21:01
SLG46826 factory setting for IO6?

With IO6 connected to SDA, it seems to fail to program, giving the "Chip is absent or misplaced" error.

During the programming attempt, SDA reaches 3.3V about 1mS after starting, but goes to 0 at about 3.3mS.

Is a factory-set value for IO6 being asserted then, and if so, can it be changed?

Keywords:
Device:
Device Number:
SLG46826V
pavloZ
Offline
Last seen:1 year 1 week ago
工作人员
加入:2018-01-31 12:50
Hi Lottabull,

Hi Lottabull,

please check your device connection, IO6 is just GPO pin and not dedicated for programming.

lottabull
Offline
Last seen:6 months 2 weeks ago
加入:2018-03-02 21:01
I have IO6 connected to SDA

I have IO6 connected to SDA by PCB trace.

My thought was the factory setting of IO6 might be holding SDA low.

pavloZ
Offline
Last seen:1 year 1 week ago
工作人员
加入:2018-01-31 12:50
你的意思是它possibble

你的意思是它possibble to reassign IO6 to support SDA signal, wright? This device has only PIN8 SCL and PIN9 SDA dedicated for programming and they couldn't be reassigned.

lottabull
Offline
Last seen:6 months 2 weeks ago
加入:2018-03-02 21:01
No, we are manipulating the

No, we are manipulating the SDA signal at certain times with output from IO6.

I am concerned that the factory setting for IO6 might be output enabled and driven low.

pavloZ
Offline
Last seen:1 year 1 week ago
工作人员
加入:2018-01-31 12:50
Hi Lottabull,

Hi Lottabull,

IO6 (PIN10) has option to be digital outptut only and it configured as 1x push-pull with 1M pull-down resistor as a default. Programming process is finishing by device reset and it drops your SDA line down. That's why this error appears. This couldn't be changed as factory-set because the IO6 has no digital input mode. Another pins have this mode as a default and keep HI-Z during reset.

lottabull
Offline
Last seen:6 months 2 weeks ago
加入:2018-03-02 21:01
Thanks very much.

Thanks very much.

I confirmed that a chip fresh off the reel will hold IO6 low.

Switching to IO2(PIN4) has fixed our problem.