Hi there.. thanks for coming to the forums. Exciting news! we’re now in the process of moving to our new forum platform that will offer better functionality and is contained within the main Dialog website. All posts and accounts have been migrated. We’re now accepting traffic on the new forum only - please POST any new threads at//www.wsdof.com/support. We’ll be fixing bugs / optimising the searching and tagging over the coming days.
8 posts / 0 new
Last post
Daniel.Landherr
Offline
Last seen:1 year 7 months ago
Joined:2014-06-19 20:36
Programming OTP through Debug Access Port

I am seeing times when the OTP programming is not successful, looks like it misses an entire FIFO.

Details:

Accessing memory via DAP (Debug Access Port).
1) CPU Halted
2) OTP Access
* CLK_AMBA_REG = OTP_ENABLE
* SPOTP_TEST_REG = LDO_OTP_WRITE

3) OTP Write
* OTPC_MODE_REG = 0
* OTPC_CELADR_REG = starting address value
* OTPC_NWORDS_REG = number of words to be written
* CPMC_MODE_REG = XPMC_MODE_APROG
* repeat the following for each word to write
** OTPC_FFPRT_REG = next data value to write
NOTE: The code processing the write commands repeats every 0.000460 Seconds.

4) Read back all values to verify programming was successful

The failure seen on a small percentage of devices (5 of 4660) is that values are skipped during the write process.
The skipped values seem to occur in groups of 8, the values are skipped without incrementing the write address. As seen below the values intended for address 2000050C was written to 200004EC. After a group of 8 skipped values, the values written continue correctly for a while and then another group of 8 address values is skipped; in a write sequence of 7211 addresses 100 – 200 groups of 8 addresses values where skipped.

Example (highlighted values are mismatches)
Address Expected Write Value Actual Value Written to address listed Artificially re-aligning values. Result if Value had not been skipped
200004E8 47084910 47084910 47084910
200004C 46712004 8009F3EF跳过了
200004F0 D0034208 47084908跳过
200004F4 8009F3EF 8008F3EF Skipped
200004F8 4708490D 47084906 Skipped
200004FC 8008F3EF E7FEE7FE Skipped
20000500 4708490B E7FE Skipped
20000504 46712004 20000475 Skipped
20000508 D0034208 20000451 Skipped
2000050C 8009F3EF 200022CB 8009F3EF
20000510 47084908 200022C5 47084908
20000514 8008F3EF 20002645 8008F3EF
20000518 47084906 21014308 47084906
2000051C E7FEE7FE 46030389 E7FEE7FE
20000520 E7FE 4937430B E7FE
20000524 20000475 4 b37800b 20000475
20000528 20000451 80084318 20000451
2000052C 200022CB 43022009 200022CB
20000530 200022C5 4770804A 200022C5
20000534 20002645 880A4932 20002645
20000538 21014308 19B230F 21014308
2000053C 46030389 439A0700 46030389
20000540 4937430B 43020D80 4937430B
20000544 4B37800B 4770800A 4B37800B

Device:
Daniel.Landherr
Offline
Last seen:1 year 7 months ago
Joined:2014-06-19 20:36
Using DA14581 in a Murata

Using DA14581 in a Murata module

PM_Dialog
Offline
Last seen:2天8小时前
Staff
Joined:2018-02-08 11:03
Hi Daniel.Landherr,

Hi Daniel.Landherr,

Apologies for the delay. Could you please clarify how you are doing the OTP programming and which tool are you using?

Thanks, PM_Dialog

Daniel.Landherr
Offline
Last seen:1 year 7 months ago
Joined:2014-06-19 20:36
We developed an interface

We developed an interface through the Debug Access Port that directly programs the memory using the settings listed above.

3V on VBAT(pin5)
6.8V on VPP(pin26)
communicating using the SWD (Single Wire Debug) Port on SWCLK/P1_4(pin15) and SWDIO/P1_5(pin16).

PM_Dialog
Offline
Last seen:2天8小时前
Staff
Joined:2018-02-08 11:03
Hi Daniel.Landherr,

Hi Daniel.Landherr,

If I am able to understand correctly, you have developed a custom tool, so in that case I am not able to provide any support for your issue. Be aware that it is highly recommended to use our tools that we can provide support. Could you please let me know if there is a specific reason why you are not using the Smart Snippet in order to program the OTP? Did you try to use it?

Thanks, PM_Dialog

Daniel.Landherr
Offline
Last seen:1 year 7 months ago
Joined:2014-06-19 20:36
Smart Snippets is good for

Smart Snippets is good for development use but it is not suitable for use in an automated manufacturing test environment.

PM_Dialog
Offline
Last seen:2天8小时前
Staff
Joined:2018-02-08 11:03
Hi Daniel.Landherr,

Hi Daniel.Landherr,

Please check the Production Line Tool (PLT) from our support portal. This tool has been designed for production test and programming unit that enables you to reduce cost and increase throughput in volume test & programming of units centered around the DA1458x family. You could find more information about this tool under the following link:

https://support.dialog-semiconductor.com/connectivity/reference-design/production-line-tool

Thanks, PM_Dialog

MHv_Dialog
Offline
Last seen:1 month 3 weeks ago
Staff
Joined:2013-12-06 15:10
I have taken this issue

当用例是非标准时,我已经在对话框中直接升级并在内部升级它。Note to any other users:Daniel Landerrr正在做的是在他非常特殊的情况下唯一的感觉。其他客户将收到支持尝试复制此设置。唯一的建议和支持的制造选项保留了生产线工具。