Hi there.. thanks for coming to the forums. Exciting news! we’re now in the process of moving to our new forum platform that will offer better functionality and is contained within the main Dialog website. All posts and accounts have been migrated. We’re now accepting traffic on the new forum only - please POST any new threads at//www.wsdof.com/support. We’ll be fixing bugs / optimising the searching and tagging over the coming days.
4 posts / 0 new
Last post
Jun-ichi Tobe
Offline
Last seen:5 months 1 week ago
加入:2016-04-01 10:39
Current consumption at startup 2

Hi support team!

It is a related question of "Current consumption at startup" that I posted last week.
I checked the operation with reference to the information you have already sent.
By setting the default STARTUP_SLEEP_DELAY_DEFAULT setting value to less than 2 seconds,
it is now possible to sleep more quickly.
However, when I set a value of about 1 second or less,
there is still time to sleep for about 1 second regardless of the setting value.
What kind of cause do you think is?

Since we do NOT plan to use XTAL 32k, CFG_LP_CLK LP_CLK_RCX20 is defined in da 1458x_config_advanced.h.

regards,

Jun-ichi

Device:
MT_dialog
Offline
Last seen:1 month 2 weeks ago
工作人员
加入:2015-06-08 11:34
Hi Jun-ichi Tobe,

Hi Jun-ichi Tobe,

The 585 uses a different stack than the 580 and supports new features (like the Secure Connections), the delay that you mention comes from the rwip_schedule(), which is a ROM function, and this delay in sleeping is due to the key generation of the feature mentioned above, you will not be able to ommit that. Is there any specific reason for wanting to reduce that always on state ? Does this delay in sleeping induces any issues to your device ? Since this extra power consumption occurs only during boot up.

Thanks MT_Dialog

Jun-ichi Tobe
Offline
Last seen:5 months 1 week ago
加入:2016-04-01 10:39
Hi MT_Dialog!

Hi MT_Dialog!
Thank you very much for your support.

I comment as follows.
I use a rechargeable battery with a very small capacity.
Therefore, it can not consume current for a long time.
Considering the characteristics of the battery, we are examining how short it should be to the present.
I would like to prioritize the current consumption rather than the new function,
so it would be great to teach me how to disable the use of each new function.

regards,

Jun-ichi

MT_dialog
Offline
Last seen:1 month 2 weeks ago
工作人员
加入:2015-06-08 11:34
Hi Jun-ichi Tobe,

Hi Jun-ichi Tobe,

Well, i dont think that there is a way to disable that, as mentioned this is a ROM function and you cannot just disable it. So, you are just trying to minimize the power consumption of the device, not because the extra power draw when bootup causes you any issues ? Do you expect a number of boot ups during the lifetime of the product ? Since as mentioned this will occur just once during booting up.

Thanks MT_dialog